• S11 20kv Oil-Immersed Distribution Double-Winding Three-Phase Transformer
  • S11 20kv Oil-Immersed Distribution Double-Winding Three-Phase Transformer
  • S11 20kv Oil-Immersed Distribution Double-Winding Three-Phase Transformer
  • S11 20kv Oil-Immersed Distribution Double-Winding Three-Phase Transformer
  • S11 20kv Oil-Immersed Distribution Double-Winding Three-Phase Transformer
  • S11 20kv Oil-Immersed Distribution Double-Winding Three-Phase Transformer

S11 20kv Oil-Immersed Distribution Double-Winding Three-Phase Transformer

Application: Power, Electronic, Rectifier, Audio
Phase: Three
Core: Core-type Transformer
Cooling Method: Oil-immersed Type Transformer
Winding Type: Multi-winding Transformer
Certification: ISO9001
Customization:
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2024

Suppliers with verified business licenses

Shandong, China
Importers and Exporters
The supplier has import and export rights
Cooperated with Fortune 500
This supplier has Cooperated with Fortune 500 companies
Patents Awarded
The supplier had awarded 1 patents, you can check the Audit Report for more information
to see all verified strength labels (27)

Basic Info.

Model NO.
S11 20 kvoil-Immersed Distribution Transformer
Usage
Power Transformer, Distribution Transformer
Frequency Characteristics
High Frequency
Shape of Core
U
Brand
Peak Transformer
Transport Package
Wooden Box or Pallet
Specification
1240x780x1360mm
Trademark
Zhifeng Transformer
Origin
China
HS Code
8504210000

Product Description


S11 20kv Oil-Immersed Distribution Double-Winding Three-Phase Transformer

Product introduction

S11, S13 series of fully sealed oil-immersed transformers are suitable for AC 50Hz, the original working voltage 20kV and below the power system, as petroleum, metallurgy, chemical, textile, light industry and other enterprises and large dust places of the distribution transformer.

Characteristics of the product
Iron Core:
The core is cold rolled silicon copper sheet with high permeability magnetic grain orientation. The iron core is a new type of iron core, full oblique joint stacking type iron core, the iron core column is a circular section of multi-step steps, and the iron yoke and the iron core are equal sections.

Winding:
The winding adopts corrugated oil channel, no paint dipping process, and tight tape binding; The winding are concentric coils: the high voltage winding has a tap required for the tapping voltage, which is led to the tap-changer, the switch is installed on the box cover, and the power supply can be changed before the tapping voltage

Safety protection device:
30~2000kVA transformer is equipped with pressure relief valve;
Gas relays with alarm and tripping terminals can be installed according to user requirements;

Oil temperature measuring device:
The transformer is equipped with a glass thermometer tube base, the tube base is located on the top of the tank, and extends into the oil 120±10mm; 1000~2000KVA transformer equipped with outdoor signal thermometer;

Transformer tank:
The transformer fuel tank is composed of corrugated wall, and the surface is made of dust spraying and firm paint film. The corrugated heat sink not only has the cooling function, but also has the "breathing" function. The elasticity of the ripple heat sink can compensate for the change of the transformer oil volume caused by the temperature rise. Therefore, the fully sealed transformer has no oil storage cabinet, reducing the overall height of the transformer; the transformer in the packaging of the vacuum oil filling process, completely remove the moisture in the transformer, the transformer oil does not contact with the air. Effectively prevent oxygen and moisture from invading the transformer and reduce the transformer insulation performance and transformer oil aging, so conduct oil sample test irregularly

S11 20kv Oil-Immersed Distribution Double-Winding Three-Phase Transformer
S11 20kv Oil-Immersed Distribution Double-Winding Three-Phase Transformer

Technical parameter
S13-M type 20kV oil-immersed distribution transformer

Rated capacity (kVA)
Voltage combination
Join group label
No-load loss(W)
Load
loss
(W)

No-load
current  (%)

Short circuit
impedance  (%)
 
high pressure
(kV)

High pressure tap range(%)

Low pressure
(kV)
         
50 20
22
24
±5±2×2.5% 0.4 Dyn11 Yyn0 170 1270/1210 2.00 6.5
100 230 2120/2020 1.80 6.5
125 270 2500/2380 1.70 6.5
160 290 2970/2830 1.60 6.5
200 340 3500/3330 1.50 6.5
250 410 4160/3960 1.40 6.5
315 490 5010/4770 1.40 6.5
400 580 6050/5760 1.30 6.5
500 690 7280/6930 1.20 6.5
630 830 8280 1.10 6.5
800 980 9900 1.00 6.5
1000 1150 12150 1.00 6.5
1250 1410 14670 0.90 6.5
1600 1700 17550 0.80 6.5
Note: 1,The load loss above the slash line in the table applies to the Dynl1 connection group, and the load loss value below the slash line applies to the Yyn0 connection group.
2,other capacity of the product performance parameters, determined by the user and the manufacturer.

Certification certificate
S11 20kv Oil-Immersed Distribution Double-Winding Three-Phase Transformer
S11 20kv Oil-Immersed Distribution Double-Winding Three-Phase Transformer
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Diamond Member Since 2024

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company
Number of Employees
21
Year of Establishment
2011-07-05